Sale!
In Stock

New iCare TA01i Tonometer

Original price was: $2,350.Current price is: $1,650.

iCare TA01i Tonometer Included with this unit is:

  • New in Box iCare Tonometer
  • New batteries
  • Box of Probes
  • OEM Case
  • Warranty card (2 years warranty)
Brand:iCare
SKU: 8560ITA01iT Category: Tags: , ,

Description

iCare TA01i Tonometer

quick and easy IOP measurement
TA01i Tonometer is the first rebound tonometer introduced to the world by iCare. The original iCare tonometer is the right choice for a reliable basic device. The ease of use makes it an important instrument for general practitioners, optometrists, occupational health care, pharmacies and other medical personnel. It is handy in clinics for both adult and pediatric readings as well as in the field, i.e. in mass glaucoma screenings.

Ideal for glaucoma screenings anywhere
Requiring no drops or specialized training makes IOP measuring quick and easy for screening programs and humanitarian missions around the world. Since single-use probes are used for measurement, there is no risk of microbiological contamination.

Efficient patient flow
Rebound tonometry eliminated the need for anesthetic drops that means reduced patient waiting times and lower costs. As a result, the patient flow can be kept dynamic even with massive screening programs.

Considerable time and money savings
The device does not need any calibration and that means the reduction of the time-consuming maintenance and increased service costs associated with calibration. Also, eye care professionals can concentrate on taking readings—not on the device’s settings between eyes or between patients.

The iCare TA01i tonometer provides accurate, objective intraocular pressure (IOP) readings of even the most demanding patients, such as children or dementia patients. With iCare TA01i, you can measure IOP when the patient is in a sitting or standing position.

The iCare TA01i tonometer is supremely durable and will last for years. It does not need calibration and thus, time-consuming maintenance. Deployment of the device requires only minimal training, which makes it suitable for use by a wide range of healthcare professionals from doctors to technicians. The iCare TA01i has an excellent quality-price ratio.

As all iCare’s tonometers, the TA01i’s working principle is based on the patented rebound technology, which eliminates corneal disruptions and patient discomfort. The exclusive rebound technology allows painless and hygienic IOP measurement without local anesthesia. There is no patient hesitation when the iCare tonometer is used on the second eye.

Key features:

  • Suitable for all patients
  • Quick to measure
  • Easy to use
  • Durable
  • Consistent and repeatable
  • No drops, air or calibration needed
PRODUCT SPECIFICATIONS
ModelTA01i
Dimensions13-32 mm x 45-80 mm x 230 mm
Weight155 g (without batteries), 250 g (4 x AA batteries)
Battery4 x AA non-rechargeable batteries
Measurement range7 – 50 mmHg
Accuracy(95 % tolerance interval relative to manometry): ±1.2 mmHg ( 20 mmHg) and ±2.2 mmHg (>20 mmHg)
Repeatability (coefficient of variation)<8%

 

Reviews

There are no reviews yet.

Be the first to review “New iCare TA01i Tonometer”

Your email address will not be published. Required fields are marked *

Name
Email
Phone
Enquiry